Medical Equipment Section (V2)

OID: 2.16.840.1.113883.10.20.22.2.23

LOINCs: #{"46264-8"}

Alias: medical-equipment

Entries Required: N/A

Internal ID: MedicalEquipmentSectionV2

IG Link

sample2

json
{
  "resourceType" : "Procedure",
  "id" : "d6b614bd-04ce-410d-8726-e1fd01dcc72a",
  "code" : {
    "text" : "Biliary Stent, May 5, 2013",
    "coding" : [ {
      "code" : "103716009",
      "display" : "Stent Placement",
      "system" : "http://snomed.info/sct"
    } ]
  },
  "performed" : {
    "dateTime" : "2013-05-12"
  },
  "status" : "completed",
  "bodySite" : [ {
    "text" : "bile duct",
    "coding" : [ {
      "code" : "28273000",
      "display" : "bile duct",
      "system" : "http://snomed.info/sct"
    } ]
  } ],
  "subject" : {
    "id" : "patient",
    "resourceType" : "Patient"
  }
}

C-CDA Equivalent: ``xml

Medical Equipment Section (V2)
ID Assigning Auth Code Date
~ ~ ~ 05/12/2013 12:00AM UTC
Biliary Stent, May 5, 2013 bile duct
``

sample1

json
{
  "resourceType" : "List",
  "entry" : [ {
    "item" : {
      "focalDevice" : [ {
        "manipulated" : {
          "uri" : "#device"
        },
        "action" : {
          "text" : "Cardiac Pacemaker",
          "coding" : [ {
            "code" : "14106009",
            "display" : "cardiac pacemaker, device (physical object)",
            "system" : "http://snomed.info/sct"
          } ]
        }
      } ],
      "performed" : {
        "dateTime" : "2013-05-12"
      },
      "resourceType" : "Procedure",
      "contained" : [ {
        "udiCarrier" : [ {
          "deviceIdentifier" : "(01)51022222233336(11)141231(17)150707(10)A213B1(21)1234",
          "issuer" : "https://www.fda.gov/"
        } ],
        "patient" : {
          "resourceType" : "Patient",
          "id" : "patient"
        },
        "id" : "device",
        "resourceType" : "Device"
      } ],
      "status" : "completed",
      "id" : "d5b614bd-01ce-410d-8726-e1fd01dcc72a",
      "code" : {
        "text" : "Biliary Stent, May 5, 2013",
        "coding" : [ {
          "code" : "103716009",
          "display" : "Stent Placement",
          "system" : "http://snomed.info/sct"
        } ]
      },
      "bodySite" : [ {
        "text" : "bile duct",
        "coding" : [ {
          "code" : "28273000",
          "display" : "bile duct",
          "system" : "http://snomed.info/sct"
        } ]
      } ],
      "subject" : {
        "id" : "patient",
        "resourceType" : "Patient"
      }
    }
  } ],
  "id" : "3e414708-0e61-4d48-8863-484a2d473a02",
  "code" : {
    "coding" : [ {
      "code" : "40388003",
      "display" : "Implant",
      "system" : "http://snomed.info/sct"
    } ]
  },
  "status" : "current",
  "mode" : "snapshot"
}

C-CDA Equivalent: ``xml

Medical Equipment Section (V2)
ID Assigning Auth Code Date
No records
Biliary Stent, May 5, 2013 bile duct Cardiac Pacemaker
``